IRI:
http://sewernet.hsm.umontpellier.fr/SewerNet#
Current version :
SewerNet v1.1 includes additional annotations in English and French
Authors :
Batoul Haydar, Nanée Chahinian and Maria Keet
Contributors :
Franca Debole and Francesca Frontini
Imported Ontologies :
https://www.loa.istc.cnr.it/ontologies/DOLCE-Lite.owl (visualise it with LODE )
Other visualisation :
Ontology source - WebVowl

Abstract

SewerNet describes the structure and functioning of wastewater and stormwater networks and their elements. SewerNet is aligned with the DOLCE-lite foundational ontology and imports a few axioms from the Time ontology for interoperability providing a well-established semantic basis for modelling sewer networks. By adhering to INSPIRE EU directive and the RAEPA geostandard, SewerNet provides a structured framework facilitating the integration of multi-source data, enabling a unified view of information.

Table of Content

  1. Introduction
  2. Classes
  3. Object Properties
  4. Named Individuals
  5. Annotation Properties
  6. General Axioms
  7. Namespace Declarations

Introduction

Sewer Network Ontology SewerNet v1.1

Classes

Air valvec back to ToC or Class ToC

IRI: http://sewernet.hsm.umontpellier.fr/SewerNet#AirValve

Sewer air release valve
has super-classes
Apparatusc
is disjoint with
Connection pointc, Flowmeterc, Valvec

Apparatusc back to ToC or Class ToC

IRI: http://sewernet.hsm.umontpellier.fr/SewerNet#Apparatus

A node where equipment and its casing (such as a valve and valve box, perforation for individual connections, etc.) are positioned, either located in a structure or not (as in the case of a branch connection) Subclasses include the msot common apparatus.
has super-classes
Nodec
has sub-classes
Air valvec, Connection pointc, Flowmeterc, Valvec

Attribute authorc back to ToC or Class ToC

IRI: http://sewernet.hsm.umontpellier.fr/SewerNet#AttributeAuthor

The author of the attribute data acquisition (if different from the author of the geolocalisation)
has super-classes
Objet socialc
participant inop some Geolocationc

Cementc back to ToC or Class ToC

IRI: http://sewernet.hsm.umontpellier.fr/SewerNet#Cement

Hydraulic binder used in the preparation of concrete and in the production of flooring, bricks, plasters, and limes (asbestos cement, fibre cement, fiber-cement)
has super-classes
Materialc
is disjoint with
Concretec, Glassc, Masonryc, Metallicc, Natural stonec, Plasticc

Channelc back to ToC or Class ToC

IRI: http://sewernet.hsm.umontpellier.fr/SewerNet#Channel

An open conduit that directs flow
has super-classes
Conduitc

Collectionc back to ToC or Class ToC

IRI: http://sewernet.hsm.umontpellier.fr/SewerNet#Collection

Conduit mainly used for collection of sewage water
has super-classes
Conduit functionc
is disjoint with
Transportc

Combined conduitc back to ToC or Class ToC

IRI: http://sewernet.hsm.umontpellier.fr/SewerNet#CombinedConduit

A conduit conveying wastewater and stormwater under normal operating conditions
has super-classes
Conduit categoryc
is disjoint with
Stormwater conduitc, Wastewater conduitc

Combined networkc back to ToC or Class ToC

IRI: http://sewernet.hsm.umontpellier.fr/SewerNet#CombinedNetwork

Wastewater and stormwater collection network
has super-classes
Networkc
is disjoint with
Stormwater networkc, Wastewater networkc

Combined wastewaterc back to ToC or Class ToC

IRI: http://sewernet.hsm.umontpellier.fr/SewerNet#CombinedWastewater

A combined wastewater sewer is a type of sewer system that collects sanitary sewage and stormwater runoff in a single pipe system.
has super-classes
Sewer waterc

Concretec back to ToC or Class ToC

IRI: http://sewernet.hsm.umontpellier.fr/SewerNet#Concrete

It includes among others: reinforced concrete, composite concrete, prestressed reinforced concrete
has super-classes
Materialc
is disjoint with
Cementc, Glassc, Masonryc, Metallicc, Natural stonec, Plasticc

Conduitc back to ToC or Class ToC

IRI: http://sewernet.hsm.umontpellier.fr/SewerNet#Conduit

A set of pipes joined at their ends, with identical physical characteristics (diameter, material, etc.), spatially represented by a line
has super-classes
Network elementc
specific constant constituentop some Materialc
weak connectionop some Nodec
generic dependentop some Conduit functionc
has qualityop some Conduit circulation modec
has qualityop some Diameterc
has qualityop some Dimensionc
has qualityop some Flow directionc
has qualityop some Lengthc
has qualityop some Shapec
has qualityop some Slopec
has sub-classes
Channelc, Pipec

Conduit categoryc back to ToC or Class ToC

IRI: http://sewernet.hsm.umontpellier.fr/SewerNet#ConduitCategory

Conduit category according to the nature of the water conveyed
has super-classes
non physical objectc
has bearerop some Conduitc
generically dependent onop some Sewer waterc
has sub-classes
Combined conduitc, Stormwater conduitc, Wastewater conduitc

Conduit circulation modec back to ToC or Class ToC

IRI: http://sewernet.hsm.umontpellier.fr/SewerNet#ConduitCirculationMode

Fluid flow regime in the conduit
has super-classes
qualityc
inherent inop some Conduitc
has sub-classes
Force mainc, Gravityc, Vacuumc

Conduit defectc back to ToC or Class ToC

IRI: http://sewernet.hsm.umontpellier.fr/SewerNet#ConduitDefect

Type of defect that required repair
has super-classes
featurec
part ofop some Network elementc
participant inop some Repairc
has sub-classes
Crackc, Defective jointc, Dislocationc, Holec, Longitudinal breakagec, Net breakagec

Conduit functionc back to ToC or Class ToC

IRI: http://sewernet.hsm.umontpellier.fr/SewerNet#ConduitFunction

Function of a conduit within the collective sewer network
has super-classes
non physical objectc
generically dependent onop some Conduitc
has sub-classes
Collectionc, Transportc

Conduit pointc back to ToC or Class ToC

IRI: http://sewernet.hsm.umontpellier.fr/SewerNet#ConduitPoint

A point on a conduit
has super-classes
Network element partc
weak connectionop only Nodec
has sub-classes
Downstream conduit extremityc, Upstream conduit extremityc

Connection pointc back to ToC or Class ToC

IRI: http://sewernet.hsm.umontpellier.fr/SewerNet#ConnectionPoint

Branch pipe for individual connection
has super-classes
Apparatusc
is disjoint with
Air valvec, Flowmeterc, Valvec

Coordinatec back to ToC or Class ToC

IRI: http://sewernet.hsm.umontpellier.fr/SewerNet#Coordinate

The position of a point in space can be expressed in the form of geocentric Cartesian coordinates (using a three-dimensional reference system with its origin at the Earth's center of mass, as an intermediate system during calculations), or in the form of geographic coordinates (in the format: longitude, latitude, and ellipsoidal height), or in planar coordinates (on a projected cartographic representation)
has super-classes
space regionc
q location ofop some Géométriec
has sub-classes
X Coordinatec, Y Coordinatec

Crackc back to ToC or Class ToC

IRI: http://sewernet.hsm.umontpellier.fr/SewerNet#Crack

Cracked conduit
has super-classes
Conduit defectc

Date-time intervalc back to ToC or Class ToC

IRI: http://www.w3.org/2006/time#DateTimeInterval

DateTimeInterval is a subclass of ProperInterval, defined using the multi-element DateTimeDescription.
has super-classes
Proper intervalc

Decommissionnedc back to ToC or Class ToC

IRI: http://sewernet.hsm.umontpellier.fr/SewerNet#Decommissioned

The facility is no longer used and is being or has been decommissioned.
has super-classes
Utility object statusc

Defective jointc back to ToC or Class ToC

IRI: http://sewernet.hsm.umontpellier.fr/SewerNet#DefectiveJoint

Joint défectueux
has super-classes
Conduit defectc

Detention basinc back to ToC or Class ToC

IRI: http://sewernet.hsm.umontpellier.fr/SewerNet#RetentionBasin

Structure for the storage of wastewater and/or stormwater
has super-classes
Structurec
is disjoint with
Discharge structurec, Drainc, Manholec, Pumping stationc, Spillwayc, Treatment plantc

Diameterc back to ToC or Class ToC

IRI: http://sewernet.hsm.umontpellier.fr/SewerNet#Diameter

has super-classes
physical qualityc
inherent inop some Conduitc
inherent inop some Manhole coverc

Dimensionc back to ToC or Class ToC

IRI: http://sewernet.hsm.umontpellier.fr/SewerNet#Dimension

Dimensions of a non-circular conduit
has super-classes
physical qualityc
inherent inop some Conduitc

Discharge structurec back to ToC or Class ToC

IRI: http://sewernet.hsm.umontpellier.fr/SewerNet#DischargeStructure

Discharge (outlet) of wastewater or stormwater into the natural environment
has super-classes
Structurec
is disjoint with
Drainc, Manholec, Pumping stationc, Detention basinc, Spillwayc, Treatment plantc

Dislocationc back to ToC or Class ToC

IRI: http://sewernet.hsm.umontpellier.fr/SewerNet#Dislocation

Dislocation of pipe(s) from the pipeline
has super-classes
Conduit defectc

Disusedc back to ToC or Class ToC

IRI: http://sewernet.hsm.umontpellier.fr/SewerNet#Disused

L'ouvrage n'est plus utilisé, mais il n'est pas en cours ni n'a fait l'object d'un arrêt definitif de service
has super-classes
Utility object statusc

Downstream conduit extremityc back to ToC or Class ToC

IRI: http://sewernet.hsm.umontpellier.fr/SewerNet#DownstreamConduitExtremity

Final point of a conduit (terminal point)
has super-classes
Conduit pointc

Drainc back to ToC or Class ToC

IRI: http://sewernet.hsm.umontpellier.fr/SewerNet#Inlet

An opening, often located along the sidewalk or sometimes on the roadway, designed to collect runoff water and discharge it into the sewer system
has super-classes
Structurec
is disjoint with
Discharge structurec, Manholec, Pumping stationc, Detention basinc, Spillwayc, Treatment plantc

Duration descriptionc back to ToC or Class ToC

IRI: http://www.w3.org/2006/time#DurationDescription

Description of temporal extent structured with separate values for the various elements of a calendar-clock system. The temporal reference system is fixed to Gregorian Calendar, and the range of each of the numeric properties is restricted to xsd:decimal
has super-classes
Generalized duration descriptionc
has sub-classes
yearc

Elevationc back to ToC or Class ToC

IRI: http://sewernet.hsm.umontpellier.fr/SewerNet#Elevation

The altitude of a point is the coordinate used to express the vertical difference between that point and a reference surface close to the geoid
has super-classes
spatial location qc
inherent inop some Network element partc
inherent inop some Nodec
has sub-classes
Invert elevationc, Rim elevationc

Flow directionc back to ToC or Class ToC

IRI: http://sewernet.hsm.umontpellier.fr/SewerNet#FlowDirection

Direction of flow in the collective sewer pipe
has super-classes
physical qualityc
inherent inop some Conduitc

Flowmeterc back to ToC or Class ToC

IRI: http://sewernet.hsm.umontpellier.fr/SewerNet#Flowmeter

Flow measurement device
has super-classes
Apparatusc
is disjoint with
Air valvec, Connection pointc, Valvec

Force mainc back to ToC or Class ToC

IRI: http://sewernet.hsm.umontpellier.fr/SewerNet#ForceMain

Water flows in the conduit under pressure due to a pumping system
has super-classes
Conduit circulation modec
is disjoint with
Gravityc, Vacuumc

Functionalc back to ToC or Class ToC

IRI: http://sewernet.hsm.umontpellier.fr/SewerNet#Functional

The facility is functional.
has super-classes
Utility object statusc

Gelocation qualityc back to ToC or Class ToC

IRI: http://sewernet.hsm.umontpellier.fr/SewerNet#GeolocationQuality

Accuracy class pursuant to the amended inter-ministerial Decree of 15 February 2012 Class A: Accuracy class of less than 40 cm Class B: Accuracy class greater than 40 cm and less than 1.50 m Class C: Accuracy class greater than 1.50 m
has super-classes
temporal qualityc
inherent inop some Geolocationc
has sub-classes
Geolocation quality XYc, Geolocation quality Zc

Generalized duration descriptionc back to ToC or Class ToC

IRI: http://www.w3.org/2006/time#GeneralDurationDescription

Description of temporal extent structured with separate values for the various elements of a calendar-clock system.
has super-classes
Temporal durationc
has sub-classes
Duration descriptionc
is in range of
has duration descriptionop

Geolocationc back to ToC or Class ToC

IRI: http://sewernet.hsm.umontpellier.fr/SewerNet#Geolocation

L'action de localiser des objets
has super-classes
achievementc
has qualityop some Gelocation qualityc
participantop some Attribute authorc
participantop some Network elementc
participantop some Network element partc
has timeop some Temporal entityc

Geolocation quality XYc back to ToC or Class ToC

IRI: http://sewernet.hsm.umontpellier.fr/SewerNet#GeolocationQualityXY

Planimetric geolocation quality
has super-classes
Gelocation qualityc

Geolocation quality Zc back to ToC or Class ToC

IRI: http://sewernet.hsm.umontpellier.fr/SewerNet#GeolocationQualityZ

Altimetric geolocation quality
has super-classes
Gelocation qualityc

Glassc back to ToC or Class ToC

IRI: http://sewernet.hsm.umontpellier.fr/SewerNet#Glass

Manufactured mineral substance, transparent and isotropic (fibreglass)
has super-classes
Materialc
is disjoint with
Cementc, Concretec, Masonryc, Metallicc, Natural stonec, Plasticc

Gravityc back to ToC or Class ToC

IRI: http://sewernet.hsm.umontpellier.fr/SewerNet#Gravity

Water flows through the sloped conduit because of gravity
has super-classes
Conduit circulation modec
is disjoint with
Force mainc, Vacuumc

Géométriec back to ToC or Class ToC

IRI: http://sewernet.hsm.umontpellier.fr/SewerNet#Geometry

Geometry of an entity in vector format (point, line or polygon)
has super-classes
spatial location qc
inherent inop some Network elementc
inherent inop some Network element partc
q locationop some Coordinatec

Holec back to ToC or Class ToC

IRI: http://sewernet.hsm.umontpellier.fr/SewerNet#Hole

Perforated conduit
has super-classes
Conduit defectc

Incidentc back to ToC or Class ToC

IRI: http://sewernet.hsm.umontpellier.fr/SewerNet#Incident

Phenomena affecting conduits or equipment whose occurrence is not subject to human control (leak, pollution, overflow, failure)
has super-classes
achievementc
participantop some Network elementc
participantop some Network element partc
has timeop some Temporal entityc

Inspectionc back to ToC or Class ToC

IRI: http://sewernet.hsm.umontpellier.fr/SewerNet#Inspection

Examination and monitoring of conduits and equipment
has super-classes
accomplishmentc
participantop some Network elementc
participantop some Network element partc
has timeop some Temporal entityc

Invert elevationc back to ToC or Class ToC

IRI: http://sewernet.hsm.umontpellier.fr/SewerNet#InvertElevation

Elevation of the structure's invert
has super-classes
Elevationc
inherent inop some Manholec

Lengthc back to ToC or Class ToC

IRI: http://sewernet.hsm.umontpellier.fr/SewerNet#Length

Lenght of a conduit
has super-classes
physical qualityc
inherent inop some Conduitc

Longitudinal breakagec back to ToC or Class ToC

IRI: http://sewernet.hsm.umontpellier.fr/SewerNet#LongitudinalBreakage

Broken conduit along its lenght
has super-classes
Conduit defectc

Maintenancec back to ToC or Class ToC

IRI: http://sewernet.hsm.umontpellier.fr/SewerNet#Maintenance

All operations intended to maintain or restore a network element (replacement, repair, rehabilitation)
has super-classes
accomplishmentc
participantop some Network elementc
participantop some Network element partc
participantop some Operatorc or Project ownerc
has timeop some Temporal entityc

Manholec back to ToC or Class ToC

IRI: http://sewernet.hsm.umontpellier.fr/SewerNet#Manhole

Wells covered with a slab at ground level providing access to urban water supply networks (inspection manhole)
has super-classes
Structurec
has qualityop some Invert elevationc
has qualityop some Rim elevationc
is disjoint with
Discharge structurec, Drainc, Pumping stationc, Detention basinc, Spillwayc, Treatment plantc

Manhole coverc back to ToC or Class ToC

IRI: http://sewernet.hsm.umontpellier.fr/SewerNet#ManholeCover

A cover placed on a manhole at ground level providing access to underground
has super-classes
Network element partc
has qualityop some Diameterc
specific constant constituentop some Materialc

Masonryc back to ToC or Class ToC

IRI: http://sewernet.hsm.umontpellier.fr/SewerNet#Masonry

Materials (large stones, blocks, bricks, etc.) bound together with a binder (lime, plaster, cement, etc.)
has super-classes
Materialc
is disjoint with
Cementc, Concretec, Glassc, Metallicc, Natural stonec, Plasticc

Materialc back to ToC or Class ToC

IRI: http://sewernet.hsm.umontpellier.fr/SewerNet#Material

is defined by
http://sewernet.hsm.umontpellier.fr/SewerNet.owl
Material of the network elements
has super-classes
amount of matterc
specific constant constituentop some Conduitc
specific constant constituentop some Manhole coverc
has sub-classes
Cementc, Concretec, Glassc, Masonryc, Metallicc, Natural stonec, Plasticc

Metallicc back to ToC or Class ToC

IRI: http://sewernet.hsm.umontpellier.fr/SewerNet#Metallic

It includes among others: steel, galvanized steel, copper, lead, cast iron , ductile iron
has super-classes
Materialc
is disjoint with
Cementc, Concretec, Glassc, Masonryc, Natural stonec, Plasticc

Natural stonec back to ToC or Class ToC

IRI: http://sewernet.hsm.umontpellier.fr/SewerNet#NaturalStone

Building material consisting of naturally occuring mineral substance extracted from the earth (millstone, sandstone)
has super-classes
Materialc
is disjoint with
Cementc, Concretec, Glassc, Masonryc, Metallicc, Plasticc

Net breakagec back to ToC or Class ToC

IRI: http://sewernet.hsm.umontpellier.fr/SewerNet#NetBreakage

Broken conduit
has super-classes
Conduit defectc

Networkc back to ToC or Class ToC

IRI: http://sewernet.hsm.umontpellier.fr/SewerNet#Network

Type of collective sewer network
has super-classes
physical objectc
assigned toop some Attribute authorc
assigned toop some Operatorc
assigned toop some Project ownerc
partop some Network elementc
partop some Network element partc
part ofop some Networkc
participant inop some Incidentc
participant inop some Inspectionc
participant inop some Maintenancec
participant inop some Repairc
has sub-classes
Combined networkc, Stormwater networkc, Wastewater networkc

Network elementc back to ToC or Class ToC

IRI: http://sewernet.hsm.umontpellier.fr/SewerNet#NetworkElement

Abstract base type representing an element in a network. Every element in a network provides some function that is of interest in the network.
has super-classes
physical objectc
assigned toop some Attribute authorc
assigned toop some Operatorc
assigned toop some Project ownerc
has qualityop some Géométriec
partop some Network element partc
part ofop some Networkc
participant inop some Geolocationc
participant inop some Incidentc
participant inop some Inspectionc
participant inop some Maintenancec
participant inop some Repairc
participant inop some Utility object statusc
has sub-classes
Conduitc, Nodec

Network element partc back to ToC or Class ToC

IRI: http://sewernet.hsm.umontpellier.fr/SewerNet#NetworkElementPart

Parts of Conduits and Nodes
has super-classes
physical objectc
assigned toop some Attribute authorc
assigned toop some Operatorc
assigned toop some Project ownerc
has qualityop some Elevationc
part ofop some Networkc
part ofop some Network elementc
participant inop some Geolocationc
participant inop some Incidentc
participant inop some Inspectionc
participant inop some Maintenancec
participant inop some Repairc
participant inop some Utility object statusc
has sub-classes
Conduit pointc, Manhole coverc

Nodec back to ToC or Class ToC

IRI: http://sewernet.hsm.umontpellier.fr/SewerNet#Node

A node can either represent an apparatus or a structure, where a structure may encompass one or more apparatuses
has super-classes
Network elementc
weak connection downstreamop some Conduitc
weak connection upstreamop some Conduitc
has qualityop some Elevationc
weak connectionop some Conduitc
has sub-classes
Apparatusc, Structurec

Objet socialc back to ToC or Class ToC

IRI: http://sewernet.hsm.umontpellier.fr/SewerNet#SocialObject

Commercial or civil activity of a company, as defined and stated in the articles of association
has super-classes
non physical objectc
has sub-classes
Attribute authorc, Operatorc, Project ownerc

Operatorc back to ToC or Class ToC

IRI: http://sewernet.hsm.umontpellier.fr/SewerNet#Operator

Network operator
has super-classes
Objet socialc

Pipec back to ToC or Class ToC

IRI: http://sewernet.hsm.umontpellier.fr/SewerNet#Pipe

A closed conduit that transports flow
has super-classes
Conduitc

Plasticc back to ToC or Class ToC

IRI: http://sewernet.hsm.umontpellier.fr/SewerNet#Plastic

It includes among others: PVC, CPVC, PB, PE, PEX, PP, FRP
has super-classes
Materialc
is disjoint with
Cementc, Concretec, Glassc, Masonryc, Metallicc, Natural stonec

Project ownerc back to ToC or Class ToC

IRI: http://sewernet.hsm.umontpellier.fr/SewerNet#ProjectOwner

Network owner
has super-classes
Objet socialc

Projectedc back to ToC or Class ToC

IRI: http://sewernet.hsm.umontpellier.fr/SewerNet#Projected

The facility is being designed. Construction has not yet started.
has super-classes
Utility object statusc

Proper intervalc back to ToC or Class ToC

IRI: http://www.w3.org/2006/time#ProperInterval

A temporal entity with non-zero extent or duration, i.e. for which the value of the beginning and end are different
has super-classes
Time intervalc
has sub-classes
Date-time intervalc
is disjoint with
Time instantc

Pumping stationc back to ToC or Class ToC

IRI: http://sewernet.hsm.umontpellier.fr/SewerNet#PumpingStation

Wastewater and/or stormwater pumping station
has super-classes
Structurec
has qualityop some Volumec
is disjoint with
Discharge structurec, Drainc, Manholec, Detention basinc, Spillwayc, Treatment plantc

Reclaimed waterc back to ToC or Class ToC

IRI: http://sewernet.hsm.umontpellier.fr/SewerNet#ReclaimedWater

Reclaimed water, sometimes called recycled water, is former wastewater (sewage) that has been treated to remove solids and certain impurities, and then used in sustainable landscaping irrigation or to recharge groundwater aquifers.
has super-classes
Sewer waterc

Repairc back to ToC or Class ToC

IRI: http://sewernet.hsm.umontpellier.fr/SewerNet#Repair

Network intervention carried out following a failure of said network
has super-classes
achievementc
has timeop some Temporal entityc
participantop some Conduit defectc
participantop some Network elementc
participantop some Network element partc
participantop some Operatorc or Project ownerc

Rim elevationc back to ToC or Class ToC

IRI: http://sewernet.hsm.umontpellier.fr/SewerNet#RimElevation

Elevation of the manhole cover
has super-classes
Elevationc
inherent inop some Manholec

Sanitary wastewaterc back to ToC or Class ToC

IRI: http://sewernet.hsm.umontpellier.fr/SewerNet#SanitaryWastewater

Sanitary sewers remove waste products from peoples' home and send them underground to a treatment plant.
has super-classes
Sewer waterc

Sewer waterc back to ToC or Class ToC

IRI: http://sewernet.hsm.umontpellier.fr/SewerNet#SewerWater

Classification of sewer water types
has super-classes
amount of matterc
generic dependentop some Conduit categoryc
has sub-classes
Combined wastewaterc, Reclaimed waterc, Sanitary wastewaterc, Stormwater runoffc

Shapec back to ToC or Class ToC

IRI: http://sewernet.hsm.umontpellier.fr/SewerNet#Shape

Shape of the conduit (circular, rectangular, trapezoidal, etc.)
has super-classes
physical qualityc
inherent inop some Conduitc

Slopec back to ToC or Class ToC

IRI: http://sewernet.hsm.umontpellier.fr/SewerNet#Slope

Slope of the conduit
has super-classes
physical qualityc
inherent inop some Conduitc

Spillwayc back to ToC or Class ToC

IRI: http://sewernet.hsm.umontpellier.fr/SewerNet#StormOverflow

Structure that discharges the overflow of effluents from a collective sewer conduit into a receiving natural environment
has super-classes
Structurec
is disjoint with
Discharge structurec, Drainc, Manholec, Pumping stationc, Detention basinc, Treatment plantc

Stormwater conduitc back to ToC or Class ToC

IRI: http://sewernet.hsm.umontpellier.fr/SewerNet#StormwaterConduit

A conduit conveying stormwater
has super-classes
Conduit categoryc
is disjoint with
Combined conduitc, Wastewater conduitc

Stormwater networkc back to ToC or Class ToC

IRI: http://sewernet.hsm.umontpellier.fr/SewerNet#StormwaterNetwork

Collection network exclusively for stormwater
has super-classes
Networkc
is disjoint with
Combined networkc, Wastewater networkc

Stormwater runoffc back to ToC or Class ToC

IRI: http://sewernet.hsm.umontpellier.fr/SewerNet#StormwaterRunoff

Storm wastewater drains gather rain and storm runoff and direct them to wetlands and lakes. Ditches and curb line grates are storm drains.
has super-classes
Sewer waterc

Structurec back to ToC or Class ToC

IRI: http://sewernet.hsm.umontpellier.fr/SewerNet#Structure

Node (interrupting or not) where a masonry structure (manhole, chamber, etc.) is located, which may or may not house one or more collective sewerage devices Subclasses include the most common structures.
has super-classes
Nodec
has sub-classes
Detention basinc, Discharge structurec, Drainc, Manholec, Pumping stationc, Spillwayc, Treatment plantc

Temporal durationc back to ToC or Class ToC

IRI: http://www.w3.org/2006/time#TemporalDuration

Time extent; duration of a time interval separate from its particular start position
has sub-classes
Generalized duration descriptionc, Temporal unitc, Time durationc
is in range of
has temporal durationop

Temporal entityc back to ToC or Class ToC

IRI: http://www.w3.org/2006/time#TemporalEntity

A temporal interval or instant.
is equivalent to
Time instantc or Time intervalc
has super-classes
thingc
has temporal durationop some Temporal durationc
has sub-classes
Time instantc, Time intervalc
is in domain of
has beginningop, has endop, has temporal durationop
is in range of
has timeop

Temporal unitc back to ToC or Class ToC

IRI: http://www.w3.org/2006/time#TemporalUnit

A standard duration, which provides a scale factor for a time extent, or the granularity or precision for a time position.
has super-classes
Temporal durationc
has members
unit dayni, unit hourni, unit minuteni, unit monthni, unit secondni, unit weekni, unit yearni

Time durationc back to ToC or Class ToC

IRI: http://www.w3.org/2006/time#Duration

Duration of a temporal extent expressed as a number scaled by a temporal unit
has super-classes
Temporal durationc
is in range of
has durationop

Time instantc back to ToC or Class ToC

IRI: http://www.w3.org/2006/time#Instant

A temporal entity with zero extent or duration
has super-classes
Temporal entityc
is in range of
has beginningop, has endop
is disjoint with
Proper intervalc

Time intervalc back to ToC or Class ToC

IRI: http://www.w3.org/2006/time#Interval

A temporal entity with an extent or duration
has super-classes
Temporal entityc
has sub-classes
Proper intervalc

Transportc back to ToC or Class ToC

IRI: http://sewernet.hsm.umontpellier.fr/SewerNet#Transport

Conduit mainly used for transportation of water/electr/etc over long distances to distribution points
has super-classes
Conduit functionc
is disjoint with
Collectionc

Treatment plantc back to ToC or Class ToC

IRI: http://sewernet.hsm.umontpellier.fr/SewerNet#TreatmentPlant

Wastewater treatment plant
has super-classes
Structurec
has qualityop some Volumec
is disjoint with
Discharge structurec, Drainc, Manholec, Pumping stationc, Detention basinc, Spillwayc

Under constructionc back to ToC or Class ToC

IRI: http://sewernet.hsm.umontpellier.fr/SewerNet#UnderConstruction

The facility is under construction and not yet functional. This applies only to the initial construction of the facility and not to maintenance work
has super-classes
Utility object statusc

Upstream conduit extremityc back to ToC or Class ToC

IRI: http://sewernet.hsm.umontpellier.fr/SewerNet#UpstreamConduitExtremity

Starting point of a conduit (initial point)
has super-classes
Conduit pointc

Utility object statusc back to ToC or Class ToC

IRI: http://sewernet.hsm.umontpellier.fr/SewerNet#UtilityObjectStatus

The status of an object with regards to its completion and use
has super-classes
statec
participantop some Network elementc
participantop some Network element partc
has sub-classes
Decommissionnedc, Disusedc, Functionalc, Projectedc, Under constructionc

Vacuumc back to ToC or Class ToC

IRI: http://sewernet.hsm.umontpellier.fr/SewerNet#Vacuum

Water flows due to the vacuum created in the conduit by a sunction station
has super-classes
Conduit circulation modec
is disjoint with
Force mainc, Gravityc

Valvec back to ToC or Class ToC

IRI: http://sewernet.hsm.umontpellier.fr/SewerNet#Valve

Sewer valve
has super-classes
Apparatusc
is disjoint with
Air valvec, Connection pointc, Flowmeterc

Volumec back to ToC or Class ToC

IRI: http://sewernet.hsm.umontpellier.fr/SewerNet#Volume

Volume of the structure
has super-classes
physical qualityc
inherent inop some Pumping stationc
inherent inop some Treatment plantc

Wastewater conduitc back to ToC or Class ToC

IRI: http://sewernet.hsm.umontpellier.fr/SewerNet#WastewaterConduit

A conduit conveying wastewater
has super-classes
Conduit categoryc
is disjoint with
Combined conduitc, Stormwater conduitc

Wastewater networkc back to ToC or Class ToC

IRI: http://sewernet.hsm.umontpellier.fr/SewerNet#WastewaterNetwork

Wastewater collection network
has super-classes
Networkc
is disjoint with
Combined networkc, Stormwater networkc

X Coordinatec back to ToC or Class ToC

IRI: http://sewernet.hsm.umontpellier.fr/SewerNet#XCoordinate

X coordinate in Lambert 93 (in meters)
has super-classes
Coordinatec

Y Coordinatec back to ToC or Class ToC

IRI: http://sewernet.hsm.umontpellier.fr/SewerNet#YCoordinate

Y coordinate in Lambert 93 (in meters)
has super-classes
Coordinatec

yearc back to ToC or Class ToC

IRI: http://www.w3.org/2006/time#Year

has super-classes
Duration descriptionc

Object Properties

assigned toop back to ToC or Object Property ToC

IRI: http://sewernet.hsm.umontpellier.fr/SewerNet#assignedTo

Assigns network and network elements with roles
has domain
physical objectc
has range
non physical objectc

has bearerop back to ToC or Object Property ToC

IRI: http://sewernet.hsm.umontpellier.fr/SewerNet#hasBearer

Associates conduit categories with individual conduits.
has domain
non physical objectc
has range
physical objectc

has beginningop back to ToC or Object Property ToC

IRI: http://www.w3.org/2006/time#hasBeginning

Beginning of a temporal entity
has super-properties
has timeop
has domain
Temporal entityc
has range
Time instantc

has durationop back to ToC or Object Property ToC

IRI: http://www.w3.org/2006/time#hasDuration

Duration of a temporal entity, expressed as a scaled value or nominal value
has super-properties
has temporal durationop
has range
Time durationc

has duration descriptionop back to ToC or Object Property ToC

IRI: http://www.w3.org/2006/time#hasDurationDescription

Duration of a temporal entity, expressed using a structured description

has endop back to ToC or Object Property ToC

IRI: http://www.w3.org/2006/time#hasEnd

End of a temporal entity.
has super-properties
has timeop
has domain
Temporal entityc
has range
Time instantc

has temporal durationop back to ToC or Object Property ToC

IRI: http://www.w3.org/2006/time#hasTemporalDuration

Duration of a temporal entity.

has timeop back to ToC or Object Property ToC

IRI: http://www.w3.org/2006/time#hasTime

Supports the association of a temporal entity (instant or interval) to any thing
has sub-properties
has beginningop, has endop
has range
Temporal entityc

weak connectionop back to ToC or Object Property ToC

IRI: http://www.loa-cnr.it/ontologies/DOLCE-Lite.owl#weak-connection

has characteristics : symmetric

has sub-properties
weak connection downstreamop, weak connection upstreamop

weak connection downstreamop back to ToC or Object Property ToC

IRI: http://sewernet.hsm.umontpellier.fr/SewerNet#weakConnectionDownstream

Connects nodes with downstream conduits
has super-properties
weak connectionop
has domain
physical objectc
has range
physical objectc

weak connection upstreamop back to ToC or Object Property ToC

IRI: http://sewernet.hsm.umontpellier.fr/SewerNet#weakConnectionUpstream

Connects nodes with upstream conduits
has super-properties
weak connectionop
has domain
physical objectc
has range
physical objectc

Named Individuals

unit dayni back to ToC or Named Individual ToC

IRI: http://www.w3.org/2006/time#unitDay

belongs to
Temporal unitc

unit hourni back to ToC or Named Individual ToC

IRI: http://www.w3.org/2006/time#unitHour

belongs to
Temporal unitc

unit minuteni back to ToC or Named Individual ToC

IRI: http://www.w3.org/2006/time#unitMinute

belongs to
Temporal unitc

unit monthni back to ToC or Named Individual ToC

IRI: http://www.w3.org/2006/time#unitMonth

belongs to
Temporal unitc

unit secondni back to ToC or Named Individual ToC

IRI: http://www.w3.org/2006/time#unitSecond

belongs to
Temporal unitc

unit weekni back to ToC or Named Individual ToC

IRI: http://www.w3.org/2006/time#unitWeek

belongs to
Temporal unitc

unit yearni back to ToC or Named Individual ToC

IRI: http://www.w3.org/2006/time#unitYear

belongs to
Temporal unitc

Annotation Properties

change noteap back to ToC or Annotation Property ToC

IRI: http://www.w3.org/2004/02/skos/core#changeNote

contributorap back to ToC or Annotation Property ToC

IRI: http://purl.org/dc/elements/1.1/contributor

creatorap back to ToC or Annotation Property ToC

IRI: http://purl.org/dc/elements/1.1/creator

dateap back to ToC or Annotation Property ToC

IRI: http://purl.org/dc/elements/1.1/date

definitionap back to ToC or Annotation Property ToC

IRI: http://www.w3.org/2004/02/skos/core#definition

descriptionap back to ToC or Annotation Property ToC

IRI: http://purl.org/dc/elements/1.1/description

editorial noteap back to ToC or Annotation Property ToC

IRI: http://www.w3.org/2004/02/skos/core#editorialNote

noteap back to ToC or Annotation Property ToC

IRI: http://www.w3.org/2004/02/skos/core#note

pref labelap back to ToC or Annotation Property ToC

IRI: http://www.w3.org/2004/02/skos/core#prefLabel

rightsap back to ToC or Annotation Property ToC

IRI: http://purl.org/dc/terms/rights

General Axioms

All Disjoint Classes back to ToC

Air valvec, Connection pointc, Flowmeterc, Valvec

All Disjoint Classes back to ToC

Cementc, Concretec, Glassc, Masonryc, Metallicc, Natural stonec, Plasticc

All Disjoint Classes back to ToC

Combined conduitc, Stormwater conduitc, Wastewater conduitc

All Disjoint Classes back to ToC

Combined networkc, Stormwater networkc, Wastewater networkc

All Disjoint Classes back to ToC

Discharge structurec, Drainc, Manholec, Pumping stationc, Detention basinc, Spillwayc, Treatment plantc

All Disjoint Classes back to ToC

Force mainc, Gravityc, Vacuumc

Namespace Declarations back to ToC

default namespace
http://sewernet.hsm.umontpellier.fr/SewerNet#
dc
http://purl.org/dc/elements/1.1/
dolce-lite-owl
http://www.loa-cnr.it/ontologies/DOLCE-Lite.owl#
geosparql
http://www.opengis.net/ont/geosparql#
ontologies
https://www.loa.istc.cnr.it/ontologies/
owl
http://www.w3.org/2002/07/owl#
rdf
http://www.w3.org/1999/02/22-rdf-syntax-ns#
rdfs
http://www.w3.org/2000/01/rdf-schema#
skos
http://www.w3.org/2004/02/skos/core#
terms
http://purl.org/dc/terms/
time
http://www.w3.org/2006/time#
xsd
http://www.w3.org/2001/XMLSchema#

This HTML document was obtained by processing the OWL ontology source code through LODE, Live OWL Documentation Environment, developed by Silvio Peroni .